Measuring Range: Gauge pressure -0.1…0~0.01…100MPa
Overload: 1.5 times full-scale pressure or 110MPa (whichever is smaller)
Alarm Contacts: 1~5 points
Display Range: -1999~9999
Load Capacity: 240V/3A (AC) or 30V/5A (DC)
Contact Life: 100,000 times
Accuracy: ±0.25%FS (typical), ±0.5%FS (maximum)
Stability: ±0.1%FS/year (typical), ±0.2%FS/year (maximum)
Zero Drift: ±0.03%FS/℃ (≤100kPa)
±0.02%FS/℃ (>100kPa)
Span Drift: ±0.03%FS/℃ (≤100kPa)
±0.02%FS/℃ (>100kPa)
Medium Temperature: -30℃~85℃
Storage Temperature: -40℃~85℃
Power Supply: 24VDC or 220VAC
Output Signal: Analog: 4~20mADC, 0~10/20mADC or 0/1~5VDC
Digital: RS485
Load Resistance: ≤ (U-15)/0.02Ω, ≤ (U-15)/0.02Ω, >5k
Process Connection: M20×1.5 External thread
M27×2 external thread
Clamp connection (other types can be customized)
Shell Protection: IP65 for both cable and connector connections
RELATED
RELATED
Company Address:
LOT 359611,JALAN MENGLEMBU JAYA 3.
INDUSTRI MENGLEMBU JAYA,
31450IPOH,PERAK.MALAYSIA
Sales Manager:
Leon Leung : +60 17685 7508
E-mail : marketing@atl-my.com
Copyright @ ATL PRODUCTS TECH SDN.BHD All rights reserved
Main business area: America / China